Loading

JSM Dentistry

Effect of Two Cleansing Agents on Color Stability of Two Thermoplastic Denture Base Materials

Research Article | Open Access

  • 1. Department of Prosthesis, October 6 University, Egypt
  • 2. Department of Prosthesis, Tanta University, Egypt
+ Show More - Show Less
Corresponding Authors
Mahmoud Nabil Helaly, Department of Prosthesis, Faculty of dentistry, October 6 university, Egypt
Abstract

Aim: Some patients experience adverse reactions to acrylic resin (PMMA) denture base material. Polyamide (PA) as an alternative to PMMA has however not been well documented regarding color stability. The aim of this in vitro study was to evaluate the effect of two different cleansing agents (corega and fitty dent), on color stability of two thermoplastic denture base materials (vertex thermosens and breflex).

Materials and methods: A total of 60 samples were fabricated from two different thermoplastic denture base materials (vertex thermosens and vreflex). The samples were divided into 3 groups. Each group was including twenty samples, ten samples each for vertex thermosens and 10 from breflex denture base materials. Samples of Group I were subjected to the distilled water as a control group. While samples of Group II were subjected to the corega as a cleansing agent and samples of group III were subjected to fittydent as the other cleansing agent. Effect of the two cleansing agents on the two-different thermoplastic denture base materials were evaluated and compared with regards to color stability.

Results: Regarding (vertex thermosens and breflex) both materials were relatively color stable in the two cleansing agents. “corega had less effect on color change than fittydent)

Conclusion: Corega and fittydent cleansing agents could be used safely for disinfecting denture base materials (vertex thermosens and breflex) as they had non-significant effect on color stability.

Keywords


•    Polyamide; Cleansing agents; Color stability; 
Spectrophotometer

Citation

Helaly MN, Alam-Eldein AM, El-Sheikh AM (2018) Effect of Two Cleansing Agents on Color Stability of Two Thermoplastic Denture Base Materials. JSM Dent 6(2): 1110

INTRODUCTION

Many material have been used for denture base construction as acrylic resin (PMMA), nylon, poly either, etc. Unnecessary if acrylic should be mentioned at all, it should only be used to introduce the thermoplastic materials as an alternative [1].

Nylon is an alternative to acrylic resin as a denture base material and is a generic name for certain types of thermoplastic polymers known as polyamides. Nylon is a crystalline polymer, but PMMA is amorphous. This crystalline nature has a little liability to changes in physical and mechanical prosperities as has a few inter structural spaces for entrance of water, saliva and cleansing agents [2].

Color change within the denture base (PMMA) may be caused by the oxidation of the amine accelerator or by the penetration of colored solutions (nylon and PMMA). Most materials used for prosthetic treatment are subject to sorption, a process of absorption and adsorption of liquids dependent on environmental conditions [3]. Color change may be associated with porosity caused by overheating or insufficient pressure during polymerization or to excessive residual monomer, surface characteristics and microporosity in the specimens [3].

Staining of acrylic resins can lead to poor esthetics [3]. Color change of denture base materials may result in patient dissatisfaction and additional expense for replacement. Determination of color by visual means is considered highly subjective [4]. Methods used to assess changes in shade include digital analysis, projection of photographic slides, visual group ranking, and shade guide matching [4].

The spectrophotometer evaluates visible light through the color spectrum (400-700 nm) and expresses the analysis as a numerical value and is accurate method and avoids the human errors in visual methods [5]. Disinfection method should be effective without detrimental effects on the properties of materials used for fabrication of denture base. Everyday use of denture cleansers is recommended to prevent microbial colonization on denture and promote good oral health. Daily use of denture cleansers can affect the color stability of denture base material. In choosing a disinfectant for a dental prosthesis, consideration should be given to its compatibility with the type of material to be disinfected to avoid adverse effects [6,7].

MATERIALS AND METHODS

In this in-vitro study, a total of 60 samples were made from two different thermoplastic denture base materials (vertex thermosens, Vertex-Dental B.V. Headquarters Netherlands) and (breflex, bredentWeissenhorner Germany). The samples were divided into 3 groups (Figure 1).

Preparation of metal discs

Metal disc shape patterns for water sorption and water solubility (50 ± 1 mm in diameter and 0.5 ± 0.05 mm) thick were fabricated from a private engineering works by laser cutting according to ADA specification no. 12. These metal disks were used to prepare the samples for the two denture base materials [8] (Figure 2).

Preparation of samples

Samples of this study were prepared according to the manufacture instructions by injecting thermoplastic materials into special flasks with holes to receive the capsule that contained the powder of thermoplastic material [9]. The flask filled with plaster then the metal disk was put in the flask to make a mould. The sprue of the soft wax was applied to the injection channel of the flask contained the sample metal disk impeded in the plaster.

The two halves of the flask were assembled and fastened with screws. The plaster was let to harden. The flasks were placed for 10 minutes in 70ºC water to soften the wax. The flasks were opened, and the wax were removed and cleaned with boiling water. The plaster was separated with Thermo-Flow isolation. The flasks were preheated for 15 minutes in ≥ 90°C water and were put in the machine just before injection. The injection with 6.5 bars of pressure was started after 16 minutes of preheating of the cartridge at 250ºC. The complete flasks were placed in an oven (>100ºC) or in boiling water for 30 minutes. In order to achieve optimal quality of the material, the flasks were bench cooling for 20 minutes and it was then opened.

The samples were taken carefully, and the injection channels were cut off. The edges were ground with the cross standard bur. The surface was polished with silicone polishers. Thermo-Gloss and a microfiber polishing brush were used for finishing. The final finish was completed with the brush felt cloth.

Color stability evaluation

The spectrophotometer and the International Commission on Illumination (CIE) concept were used to carry out this test by measuring the light absorption of each specimen before and after immersion into corega and fittydent cleansing agents [10-12].

The apparatus used in measurements was AgilentCary5000spectrophotometers. It was manufactured according to a quality management system certified to ISO 9001.

1 The basic CIE concept is that all colors can be matched by mixing relative amounts of the three light primaries: Red (X), Green (Y), and Blue (Z) [10]. These can then be transformed to L* is a measure of lightness. The a* value represents positions on a red-green axis. As a* becomes more positive in value, the color is more red; as a* becomes more negative in value, the color becomes more green. The b* value represents positions on a yellow– blue axis. As b* becomes more positive in value, the color becomes more yellow; as b* becomes more negative in value, the color becomes more blue [10]. The equation utilized for calculating color differences in this system10: ΔE (Color Changes Value) = {(ΔL)2 +(Δa)2 +(Δb)2 }1/2 where ΔL, Δa and Δb are the differences in L, a and b values before and after immersion at each time interval. For this study, the ΔE result is used for analysis.

National Bureau of Standards (NBS) is used to quantify the color change. Critical marks of color difference according to NBS are shown in Table 1. Following formula is used to express NBS units.

NBS unit=ΔE x 0.92, Where ΔE stands for color change.

The samples were fixed to the spectrophotometer holder and the machine was turned on then the samples were tested.

All samples were evaluated for color stability before and after immersion in cleansing agents and water to evaluate the effect of cleansing agents (Figure 3 and 4).

RESULTS

Color stability

Comparison of color stability of the Thermoplastic denture base material in different cleansing agents: The results of comparison between the different groups as regarding color change are shown in Table 2 and Figure 5. The values of the color changes (ΔE) of vertex thermosens when immersed in water, corega and fittydent in comparison showed no significant difference (P-value = 0.9425). The values of the color changes (ΔE) of breflex when immersed in water, corega, fittydent in comparison showed no significant difference (p-value =0.072). Comparison of color change of the Thermoplastic denture base materials utilizing different cleansing agents using National Bureau of Standards (NBS) The mean values of color change expressed in NBS units are shown in Table 3 and Figure 6. The results revealed that all the groups showed slight change in color as interpreted Critical remarks of color difference with NBS values ranging from 0.5?1.5indicating slight color change.

DISCUSSION

Nylon with relatively low water sorption levels and melting points, was developed to overcome problems with earlier forms of denture base materials [8].

It was modified by reinforcement with glass fiber and glass spheres to increase its potential use as a denture base material. This modified material showed color stability [8]. Color stability has a long term effect on the esthetics of the denture which is a very important requirement for patient satisfaction [13]. Water sorption and solubility affect the mechanical properties and the adaptation of the denture base to the underlining structure. Using of cleansing methods for denture hygiene maintenance is mandatory [13], but cleansing methods unfortunately affect the physical properties of the denture base materials [13].

The vertex thermosens and breflex were used as a denture base materials in this study. These new materials have long chains inmolecular arrangement, that decrease the liability for water molecules to inter an desrubt the chemical structural of the denture base material which affect the color stability of the denture base material, Therfore improving the mechanical and chemical properties of the denture base materials [14,15].

Contaminated dentures need to be cleansed as part of denture hygiene regimen [16]. Chemical disinfection may cause adverse effect on the material, such as denture staining and compromised strength. To avoid adverse effects on the properties of denture base resins, disinfectant must be chosen that should have compatibility with the type of material to be disinfected [16].

The whitening effect relates to the high temperature of the water used in the solution. Irregularities and porosities present on denture surfaces offer a favorable niche to retain stain and microbial plaque [13,14].

A spectrophotometer was used to detect the color changes, which is a widely used digital image processing method for the denture base color change test because it can rule out errors due to observer bias. This system is recommended for material color difference tests because it is the most scientific color system [17- 19]. Studies reported that extrinsic factors are more frequent causes of denture base color changes than intrinsic factors [20,21].

Hu et al. [22], Investigated the pigmentation of resin materials induced by absorption or adsorption. They found that denture base materials showed color stability in water or air, but there were changes in color stability when immersed in beverages such as coffee, cleansing agents, tea, or wine. The tannic acid contained in coffee and tea are water-soluble and are known to trigger brown pigmentation. Denture cleansers cause loss of soluble component and plasticizers from the denture base resins. Higher ionic concentration of denture cleansers compared to water led to a higher release of soluble components. Further absorption of water and other salivary components by the denture base materials leads to surface roughness and color change [23,24]. In the study of Lai et al. [25], The color stability of copolyamide, silicone and heat-polymerized acrylic resins as removable gingival flange materials were evaluated by a spectrophotometer after 7, 14, 30, 120, and 180 days of immersion in staining solutions of coffee and tea. Copolyamide had the greatest staining in tea solution and the silicone material in coffee solution. The color changes of silicone and copolyamide materials stored in coffee solution for 180 days were greater than 3 NBS (National Bureau of Standards) units, which would be characterized considerable and deliberated clinically unacceptable. Takabayashi [26], Compared the color stability of six thermoplastic denture resin materials (three polyamides, two polycarbonates and a polyethylene terephthalate) after being soaked in coffee and curry solutions for 60 hours. In that study, three polyamides had considerable color change in the curry solution and two of them showed considerable color change after soaking in the coffee solution. It was found that the frequency of amide groups along the chain had affected the color stability, water sorption and the chemical properties of each type of nylon. Another attributed reason could be the differences in finishing and polishing of nylon materials compared to PMMA. Rougher surfaces are more susceptible to staining [27,28].

The effects of three sodium perborate-containing denture cleansers (Corega, PR-Protefix, VA-Valclean) were evaluated on the surface roughness, hardness, and color stability of two polyamides (Valplast and Deflex), a butadiene styrene copolymer PMMA, and a PMMA polymer as a control group. Surface roughness of the polyamide increased after 20 days of repeated immersion regardless of the type of the solution used. Valplast had a higher initial surface roughness which increased after the immersion. This study also showed that no changes occurred in the color of polyamides in these solutions.

The study evaluated the effects of two denture cleansing methods [Val-Clean (peroxide cleanser) and Corega plus microwaving] on 3-D surface roughness, gloss and color of nylon (Valplast), and heat-polymerized acrylic PMMA denture base material for a period simulating 30 days of daily cleansing, by using an interferometric profilometer, a gloss meter, and a colorimeter. The results of this study showed that cleansing methods had no different effect on color group compared with the control group, when using the same material. However, the effect on Valplast was higher than PMMA, both at a clinically perceptible level.

The Val-Clean method was the only method that had no particular influence on the gloss of both tested materials. Corega plus microwaves significantly decreased the gloss of both materials. Surface roughness was affected significantly only by Corega plus microwaves and only for the PMMA material. The color change (as an effect of cleansing agent), was not associated with gloss or surface roughness in any of the materials. However, gloss and surface roughness were highly associated in PMMA and could be used for the prediction of each other

The present study showed that fittydent cleansing agent had the highest value of color changes when compared to water and corega, but the differences were insignificance and this may be due to that fittydent cleansing agent contain potassium mono sulfate and sodium bicarbonate which not contained in corega that may react with the coloring agents of the denture base materials used in this study not only that but also may increase the surface porosity.

CONCLUSION

1- Based on the results of this study, we can conclude thaCleansing agents had no noticeable effect on the color stability of the recent denture base materials (vertex thermosens and breflex). 2- Non significant differences were found between vertex thermosens and breflex denture base materials with the use of different cleansing agents (corega, fittydent, water) regarding color stability.

REFERENCES

1. Jorge H, Giampaolo T, Machado L. Cytotoxicity of denture base acrylic resins: A literature review. J Prosthet Dent. 2003; 90:190-193.

2. Yunnus N, Rashid A, Azmil L. Some flexural properties of a nylon denture base polymer. J Oral Rehabil. 2005; 32: 65-71.

3. Keif F, Gungor T. Comparison of effects of bleach and cleansing tablet on reflectance and surface changes of a dental alloy used for removable partial dentures. J Biomater Appl. 2003; 18: 5-14.

4. Kurtulmus H, Kumbuloglu O, Aktas T. Effects of saliva and nasal secretion on some physical properties of four different resin materials. Med Oral Patol Oral Cir Bucal. 2010; 15: 969-975.

5. oiner A. Tooth colour: a review of the literature. J Dent. 2004; 32: 3-12.

6. Machado L, Giampaolo T, Vergani E, Souza F, Jorge H. Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: Surface roughness of denture base and reline materials. J Appl Oral Sci. 2011; 19: 508-528.

7. Neppelenbroek H, Pavarina C, Vergani E, Giampaolo T. Hardness of heat polymerized acrylic resins after disinfection and and long term water immersion. J Prosthet Dent. 2005; 93: 171-176.

8. Aubrey C. Swaney A, George C. Paffenbarger D, Harold J, Caul B, Sweeney. American dental association specification no. 12 for denture base resin: second revision. J Americ Dent Asoosc. 1953; 46:54-66

9. Singh K, Gupta N. Injection molding technique for fabrication of flexible prosthesis from flexible thermoplastic denture base materials. World J Dent (JADA). 2012; 4: 303-307.

10. CIE (Commission International de l’Eclairage) Colorimetry technical report. CIE Publication No.15. 2. Vienna, Austria: Bureau Central de la CIE; 1986.

11. May K, Razzoog M, Koran M. Denture base resins: comparison study of color stability. J Prosthet Dent. 1992; 68: 78-82.

12. Chen H, Huang J, Dong X. A systematic review of visual and instrumental measurements for tooth shade matching. Quintessence Int. 2012; 43: 649-659.

13. Paranhos H, Silva Lovato C, de Souza R, Cruz P, de Freitas Pontes K, Watanabe E. Effect of three methods for cleaning dentures on biofilms formed in vitro on acrylic resin. J Prosthodont. 2009; 18: 427-431.

14. Unlu A, Altay OT, Sahmali S. The role of denture cleansers on the whitening of acrylic resins. Int J Prosthodont. 1996; 9: 266-270.

15. Tan H, Woo A, Kim S, Lamoureux M, Grace M. Effect of denture cleansers, surface finish, and temperature on Molloplast B resilient liner color, hardness, and texture. J Prosthodont. 2000; 9: 148-155.

16. Amin F, Iqbal S, Azizuddin S, Afridi F. Effect of denture cleansers on the color stability of heat cure acrylic resin. J Coll Physicians Surg Pak. 2014; 11: 787-790.

17. Crawford C, Lloyd C, Newton J, Yemm R. Denture bleaching: a laboratory simulation of patients’ cleaning procedures. J Dent. 1986; 14: 258-261.

18. Robinson J, McCabe J, Storer R. Denture bases: the effects of various treatments on clarity, strength and structure. J Dent. 1987; 15: 159- 165.

19. Verran J, Maryan CJ. Retention of Candida albicans on acrylic resin and silicone of different surface topography. J Prosthet Dent. 1997; 77: 535-539.

20. Asmussen E. Factors affecting the color stability of restorative resins. Acta Odontol Scand. 1983; 41: 11-18.

21. Polyzois G, Yannikakis S, Zissis A. Color stability of visible lightcured, hard direct denture reliners: an in vitro investigation. Int J Prosthodont. 1999; 12: 140-146.

22. Hu X, Johnston W, Seghi R. Measuring the color of maxillofacial prosthetic material. J Dent Res. 2010; 89: 1522-1527.

23. Lai Y, Lui H, Lee S. In vitro color stability, stain resistance, and water sorption of four removable gingival flange materials. J Prosthet Dent. 2003; 90: 293-300.

24. Navarro S, Correa A, Borges C, Jorge J, Urban V, Campanha N. Color stability of resins and nylon as denture base material in beverages. J Prosthodont. 2011; 20: 632-638.

25. Takabayashi Y. Characteristics of denture thermoplastic resins for non-metal clasp dentures. Dent Mater J. 2010; 29: 353-357.

26. Patel S, Gordan V, Barrett A, Shen C. The effect of surface finishing and storage solutions on the color stability of resin-based composites. J Am Dent Assoc. 2004; 135: 587-594.

27. Durkan R, Ayaz E, Bagis B, Gurbuz A, Ozturk N, Korkmaz F. Comparative effects of denture cleansers on physical properties of polyamide and polymethyl methacrylate base polymers. Dent Mater J. 2013; 32: 367- 375.

28. Polychronakis N, Polyzois G, Lagouvardos P, Papadopoulos T. Effects of cleansing methods on 3-D surface roughness, gloss and color of a polyamide denture base material. Acta Odontol Scand. 2015; 73: 353- 363

Received : 13 Aug 2018
Accepted : 29 Aug 2018
Published : 31 Aug 2018
Journals
Annals of Otolaryngology and Rhinology
ISSN : 2379-948X
Launched : 2014
JSM Schizophrenia
Launched : 2016
Journal of Nausea
Launched : 2020
JSM Internal Medicine
Launched : 2016
JSM Hepatitis
Launched : 2016
JSM Oro Facial Surgeries
ISSN : 2578-3211
Launched : 2016
Journal of Human Nutrition and Food Science
ISSN : 2333-6706
Launched : 2013
JSM Regenerative Medicine and Bioengineering
ISSN : 2379-0490
Launched : 2013
JSM Spine
ISSN : 2578-3181
Launched : 2016
Archives of Palliative Care
ISSN : 2573-1165
Launched : 2016
JSM Nutritional Disorders
ISSN : 2578-3203
Launched : 2017
Annals of Neurodegenerative Disorders
ISSN : 2476-2032
Launched : 2016
Journal of Fever
ISSN : 2641-7782
Launched : 2017
JSM Bone Marrow Research
ISSN : 2578-3351
Launched : 2016
JSM Mathematics and Statistics
ISSN : 2578-3173
Launched : 2014
Journal of Autoimmunity and Research
ISSN : 2573-1173
Launched : 2014
JSM Arthritis
ISSN : 2475-9155
Launched : 2016
JSM Head and Neck Cancer-Cases and Reviews
ISSN : 2573-1610
Launched : 2016
JSM General Surgery Cases and Images
ISSN : 2573-1564
Launched : 2016
JSM Anatomy and Physiology
ISSN : 2573-1262
Launched : 2016
JSM Dental Surgery
ISSN : 2573-1548
Launched : 2016
Annals of Emergency Surgery
ISSN : 2573-1017
Launched : 2016
Annals of Mens Health and Wellness
ISSN : 2641-7707
Launched : 2017
Journal of Preventive Medicine and Health Care
ISSN : 2576-0084
Launched : 2018
Journal of Chronic Diseases and Management
ISSN : 2573-1300
Launched : 2016
Annals of Vaccines and Immunization
ISSN : 2378-9379
Launched : 2014
JSM Heart Surgery Cases and Images
ISSN : 2578-3157
Launched : 2016
Annals of Reproductive Medicine and Treatment
ISSN : 2573-1092
Launched : 2016
JSM Brain Science
ISSN : 2573-1289
Launched : 2016
JSM Biomarkers
ISSN : 2578-3815
Launched : 2014
JSM Biology
ISSN : 2475-9392
Launched : 2016
Archives of Stem Cell and Research
ISSN : 2578-3580
Launched : 2014
Annals of Clinical and Medical Microbiology
ISSN : 2578-3629
Launched : 2014
JSM Pediatric Surgery
ISSN : 2578-3149
Launched : 2017
Journal of Memory Disorder and Rehabilitation
ISSN : 2578-319X
Launched : 2016
JSM Tropical Medicine and Research
ISSN : 2578-3165
Launched : 2016
JSM Head and Face Medicine
ISSN : 2578-3793
Launched : 2016
JSM Cardiothoracic Surgery
ISSN : 2573-1297
Launched : 2016
JSM Bone and Joint Diseases
ISSN : 2578-3351
Launched : 2017
JSM Bioavailability and Bioequivalence
ISSN : 2641-7812
Launched : 2017
JSM Atherosclerosis
ISSN : 2573-1270
Launched : 2016
Journal of Genitourinary Disorders
ISSN : 2641-7790
Launched : 2017
Journal of Fractures and Sprains
ISSN : 2578-3831
Launched : 2016
Journal of Autism and Epilepsy
ISSN : 2641-7774
Launched : 2016
Annals of Marine Biology and Research
ISSN : 2573-105X
Launched : 2014
JSM Health Education & Primary Health Care
ISSN : 2578-3777
Launched : 2016
JSM Communication Disorders
ISSN : 2578-3807
Launched : 2016
Annals of Musculoskeletal Disorders
ISSN : 2578-3599
Launched : 2016
Annals of Virology and Research
ISSN : 2573-1122
Launched : 2014
JSM Renal Medicine
ISSN : 2573-1637
Launched : 2016
Journal of Muscle Health
ISSN : 2578-3823
Launched : 2016
JSM Genetics and Genomics
ISSN : 2334-1823
Launched : 2013
JSM Anxiety and Depression
ISSN : 2475-9139
Launched : 2016
Clinical Journal of Heart Diseases
ISSN : 2641-7766
Launched : 2016
Annals of Medicinal Chemistry and Research
ISSN : 2378-9336
Launched : 2014
JSM Pain and Management
ISSN : 2578-3378
Launched : 2016
JSM Women's Health
ISSN : 2578-3696
Launched : 2016
Clinical Research in HIV or AIDS
ISSN : 2374-0094
Launched : 2013
Journal of Endocrinology, Diabetes and Obesity
ISSN : 2333-6692
Launched : 2013
Journal of Substance Abuse and Alcoholism
ISSN : 2373-9363
Launched : 2013
JSM Neurosurgery and Spine
ISSN : 2373-9479
Launched : 2013
Journal of Liver and Clinical Research
ISSN : 2379-0830
Launched : 2014
Journal of Drug Design and Research
ISSN : 2379-089X
Launched : 2014
JSM Clinical Oncology and Research
ISSN : 2373-938X
Launched : 2013
JSM Bioinformatics, Genomics and Proteomics
ISSN : 2576-1102
Launched : 2014
JSM Chemistry
ISSN : 2334-1831
Launched : 2013
Journal of Trauma and Care
ISSN : 2573-1246
Launched : 2014
JSM Surgical Oncology and Research
ISSN : 2578-3688
Launched : 2016
Annals of Food Processing and Preservation
ISSN : 2573-1033
Launched : 2016
Journal of Radiology and Radiation Therapy
ISSN : 2333-7095
Launched : 2013
JSM Physical Medicine and Rehabilitation
ISSN : 2578-3572
Launched : 2016
Annals of Clinical Pathology
ISSN : 2373-9282
Launched : 2013
Annals of Cardiovascular Diseases
ISSN : 2641-7731
Launched : 2016
Journal of Behavior
ISSN : 2576-0076
Launched : 2016
Annals of Clinical and Experimental Metabolism
ISSN : 2572-2492
Launched : 2016
Clinical Research in Infectious Diseases
ISSN : 2379-0636
Launched : 2013
JSM Microbiology
ISSN : 2333-6455
Launched : 2013
Journal of Urology and Research
ISSN : 2379-951X
Launched : 2014
Journal of Family Medicine and Community Health
ISSN : 2379-0547
Launched : 2013
Annals of Pregnancy and Care
ISSN : 2578-336X
Launched : 2017
JSM Cell and Developmental Biology
ISSN : 2379-061X
Launched : 2013
Annals of Aquaculture and Research
ISSN : 2379-0881
Launched : 2014
Clinical Research in Pulmonology
ISSN : 2333-6625
Launched : 2013
Journal of Immunology and Clinical Research
ISSN : 2333-6714
Launched : 2013
Annals of Forensic Research and Analysis
ISSN : 2378-9476
Launched : 2014
JSM Biochemistry and Molecular Biology
ISSN : 2333-7109
Launched : 2013
Annals of Breast Cancer Research
ISSN : 2641-7685
Launched : 2016
Annals of Gerontology and Geriatric Research
ISSN : 2378-9409
Launched : 2014
Journal of Sleep Medicine and Disorders
ISSN : 2379-0822
Launched : 2014
JSM Burns and Trauma
ISSN : 2475-9406
Launched : 2016
Chemical Engineering and Process Techniques
ISSN : 2333-6633
Launched : 2013
Annals of Clinical Cytology and Pathology
ISSN : 2475-9430
Launched : 2014
JSM Allergy and Asthma
ISSN : 2573-1254
Launched : 2016
Journal of Neurological Disorders and Stroke
ISSN : 2334-2307
Launched : 2013
Annals of Sports Medicine and Research
ISSN : 2379-0571
Launched : 2014
JSM Sexual Medicine
ISSN : 2578-3718
Launched : 2016
Annals of Vascular Medicine and Research
ISSN : 2378-9344
Launched : 2014
JSM Biotechnology and Biomedical Engineering
ISSN : 2333-7117
Launched : 2013
Journal of Hematology and Transfusion
ISSN : 2333-6684
Launched : 2013
JSM Environmental Science and Ecology
ISSN : 2333-7141
Launched : 2013
Journal of Cardiology and Clinical Research
ISSN : 2333-6676
Launched : 2013
JSM Nanotechnology and Nanomedicine
ISSN : 2334-1815
Launched : 2013
Journal of Ear, Nose and Throat Disorders
ISSN : 2475-9473
Launched : 2016
JSM Ophthalmology
ISSN : 2333-6447
Launched : 2013
Journal of Pharmacology and Clinical Toxicology
ISSN : 2333-7079
Launched : 2013
Annals of Psychiatry and Mental Health
ISSN : 2374-0124
Launched : 2013
Medical Journal of Obstetrics and Gynecology
ISSN : 2333-6439
Launched : 2013
Annals of Pediatrics and Child Health
ISSN : 2373-9312
Launched : 2013
JSM Clinical Pharmaceutics
ISSN : 2379-9498
Launched : 2014
JSM Foot and Ankle
ISSN : 2475-9112
Launched : 2016
JSM Alzheimer's Disease and Related Dementia
ISSN : 2378-9565
Launched : 2014
Journal of Addiction Medicine and Therapy
ISSN : 2333-665X
Launched : 2013
Journal of Veterinary Medicine and Research
ISSN : 2378-931X
Launched : 2013
Annals of Public Health and Research
ISSN : 2378-9328
Launched : 2014
Annals of Orthopedics and Rheumatology
ISSN : 2373-9290
Launched : 2013
Journal of Clinical Nephrology and Research
ISSN : 2379-0652
Launched : 2014
Annals of Community Medicine and Practice
ISSN : 2475-9465
Launched : 2014
Annals of Biometrics and Biostatistics
ISSN : 2374-0116
Launched : 2013
JSM Clinical Case Reports
ISSN : 2373-9819
Launched : 2013
Journal of Cancer Biology and Research
ISSN : 2373-9436
Launched : 2013
Journal of Surgery and Transplantation Science
ISSN : 2379-0911
Launched : 2013
Journal of Dermatology and Clinical Research
ISSN : 2373-9371
Launched : 2013
JSM Gastroenterology and Hepatology
ISSN : 2373-9487
Launched : 2013
Annals of Nursing and Practice
ISSN : 2379-9501
Launched : 2014
Author Information X