Loading

JSM Biotechnology and Biomedical Engineering

Improved Methods of Microinjection in Caenorhabditis elegans: Automation and Microfluidic Systems

Mini Review | Open Access

  • 1. Institute of Molecular and Cellular Biology, National Tsing Hua University, Taiwan
+ Show More - Show Less
Corresponding Authors
Muniesh Muthaiyan Shanmugam, Institute of Molecular and Cellular Biology, Department of Life Science, National Tsing Hua University, No. 101, Sec 2, Kuang-Fu Road, Hsinchu, Taiwan
Abstract

C. elegans has become a versatile model organism because of various advantages, such as being a small-sized non-parasitic worm with a transparent body and a short life cycle, along with the capacity to conduct in vivo live worm imaging, genetic amenability and cost-effective laboratory maintenance. It has also gained popularity because of the mapping of the developmental fate of every single cell and full genome sequencing of the worm. Further, among eukaryotic multi-cellular model organisms, C. elegans has the ability to generate a transgenic line in the shortest possible time compared to most other model organisms, which are being used to perform in vivo studies. Two methods for the transformation of C. elegans are widely used, namely, the microinjection of the transgene into the gonads and the bombardment of the transgene on the worm. The microinjection of C. elegans for the purpose of creating transgenic lines to study the effect of various genetic backgrounds is being carried out in almost every worm-based laboratory throughout the world. However, this technique of microinjection into the worm demands high technical expertise and expensive instruments, while the technique itself is low throughput. Until up to three years ago, the microinjection technique remained more or less same. This review focuses on recent advancements in relation to the microinjection technique, which involves the addition of automation via a computerassisted system and the involvement of biomicrofluidic systems in order to increase the efficiency and rate of microinjection, thereby reducing fatigue experienced by the researcher when developing transgenic lines of C. elegans.

Citation

Shanmugam MM (2016) Improved Methods of Microinjection in Caenorhabditis elegans: Automation and Microfluidic Systems. JSM Biotechnol Bioeng 3(5): 1072.

Keywords

•    Nematode worm
•    C. elegans
•    Microinjection
•    Microfluidic devices
•    Automated microinjection
•    Transgenes
•    Transgenic worms

ABBREVIATIONS

C. elegans: Caenorhabditis elegans; CAMI: Computer-Assisted Microinjection; DIC: Differential Interference Contrast; CS: Cross Section

INTRODUCTION

A nematode worm known as C. elegans has become a very versatile animal model for biological research from the time it was first used by Sydney Brenner during the second half of the 20th century to study genetics, animal behavior and development [1,2]. Furthermore, the worm has become a popular model to carry out various genetic, developmental, pathological, neurological, toxicological and aging research studies with its full genome sequenced, developmental cell fate mapped, and several libraries and mutants available [3]. Genetic modification of a model organism is a popular methodology to understand various aspects of biology and disease in a particular genotype by generating either a knock-out mutant or knock-in transgenic lines. One of the techniques used to generate transgenic lines and to alter the genome of an organism is needle microinjection [4- 8]. From the time that needle microinjection was introduced by Félix Dujardin and M.A. Barber, the techniques of microinjection have gained popularity in numerous field of biology from basic to clinical research [9-11].

Bombardment is yet another technique for the generation of transgenic lines, in which worms are shot at with genetic material bound to gold particles from a gene gun (biolistic bombardment machine). Unlike needle microinjection, bombardment can often produce integrated transgenic lines with a low copy number. However, bombardment demands more labor intensive preparation of worms, along with relatively more expensive instruments and materials than needle microinjection [8,12-14]. More comparison between the two techniques can be found in [15].

The conventional method of microinjection of C. elegans only differs slightly from that of cultured cells or oocytes. Several optical, analytical and digital instruments are required to carry out a successful microinjection procedure. An ample amount of literature is available to understand the basic microinjection procedure and the basic instruments required for this procedure, which can be found in [8,11]. Briefly, the worm is mounted onto a 2% agarose pad (the absorption of moisture content in the worm by the dry agarose pad develops an adhesive force, which immobilizes the worm on the agarose pad; as the agarose pad continuously desiccates the worm, the procedure has to be completed within few minutes of the immobilization of the worm [8]) by immersing in a drop of oil (this prevents the fast dehydration of the worm’s moisture to the surrounding air medium by evaporation), after which the worm is rotated to clearly visualize the gonads. Next, the worm is taken to the stage of an inverted microscope, aligned in an appropriate position against the needle. Using a micromanipulator, the needle is brought to the focal plane of the worm and the injection of several picoliters of reagent is performed using the injection system, followed by the recovery of the worm in an appropriate buffer [8]. This procedure demands a great deal of expertise to accurately actuate the needle such that the injection causes the least possible amount of damage to the worm. The current rate of microinjection in the traditional way is ~3-4 min per worm [3,16], which causes the researcher severe fatigue inorder to microinject a sufficient number of worms or multiple strains per day to obtain a transgenic lines. An experienced technician can produce an average of ~>3 independent transgenic lines upon microinjection of 10-50 gonads [5,8]. However, the efficiency and the success rate depend on several factors, such as the expertise level of the technician, the number of gonads being injected, the type of co-injection markers used, the method of screening the transgenic lines and toxicity of injection materials. Further, gaining a proper understanding of the microinjection technique and obtaining the expertise to carry out the technique may take several months for beginners.

Conventional C. elegans microinjection has not changed much since its introduction and the rate of microinjection has remained more or less the same. Therefore, it is necessary to develop automation processes in order to ease technical fatigue and increase the efficiency of the experiment. One event worth mentioning is the collaboration between material science, microfluidics and biology to develop biomicrofluidic devices, which have accelerated various aspect of biological research in the last decade. Microfluidic devices can regulate the fluid properties in micro-or nano-environments using simple mechanical or computer-controlled units, thereby providing greater control over the micro-environments used for any type of scientific analysis. Information on designing and fabricating biomicrofluidic devices, which are cost effective, can be found in [17-19].

This review article explains the latest automation strategies and microfluidic devices, which have been developed for the microinjection of C. elegans, thereby making this technique a high throughput technique.

Automation of microinjection for C. elegans

In order to increase the rate of microinjection of the worm to create transgenes and to reduce the fatigue felt by technicians, Gilleland et al. (2015), recently developed a CAMI system [3]. This study replaced the traditional use of an agarose pad and oil to prevent the mobilization and fast desiccation of the worm, respectively, along with temperature-sensitive Pluronic F-127 hydrogel (25%) and sodium azide (10 mM) to immobilize the worm on a glass-bottomed multi-well plate. A change in the temperature of Pluronic F-127 hydrogel (from 15?C to 25?C) will solidify the gel, resulting in complete immobilization of the worm, while the use of sodium azide anesthesia will provide a straightened worm. Thus, the prepared worm is mounted onto a microscope stage, whose temperature is regulated, while a computer-assisted imaging system is used to locate the position of the worm and its gonads, with microinjection performed using a micromanipulator and piezoelectric vibrator. (Figures 1,2) offer a pictorial representation of the automation methodology and successful microinjection of C. elegans. CAMI can work at a rate of ~25 s per target gonad. Further, the assessment of the success rate of CAMI showed improved results when compared to the conventional microinjection method, along with reduced fatigue and reduced experimentation time. Thus, Gilleland et al. (2015), improved the traditional microinjection system in worms with the introduction of an automated system, thereby increasing the rate of microinjection and the rate of success (Figure 1,2).

Microfluidic devices for microinjection

Zhao et al. (2013), developed a semi-open microfluidic device for the microinjection of various chemicals and proteins into a single intestinal cell of C. elegans in order to study cell-cell communication (Figure 3) [20]. This device has several channels and an open chamber. The inlet channel allows the worm to travel near to the suction channels, whose flow is regulated by a buffer channel, and become immobilized by the suction. The open channel provides a space for the microinjection needle’s movement in multiple directions, thereby enabling the microinjection of target molecules into the particular region of the worm. The worm can be imaged at the same time, either immediately after microinjection or the worm is recovered in the outlet channel (Figure 4). Although this device can be used for the microinjection of various chemicals into a single cell and imaging, this device was not examined for its efficiency concerning the generation of transgenic lines by the microinjection of the gonads of C. elegans. Based on the design of the biomicrofluidic system, this device will probably provide successful transgenic lines upon the microinjection of appropriate genetic material into the gonads of the immobilized worm. Further, the method for the immobilization of the worm used in Zhao et al.(2013), should reduce the damage caused to the worm, compared to the conventional method of microinjection, thereby providing efficient worm handling (Figure 3,4).

Another simple microfluidic system has been reported, where the passive immobilization of the worm takes place in a narrow channel, while the microinjection of worm gonads is carried out by a single degree of the freedom of movement of the microinjection needle, which is integrated into the microfluidic system. The rate of microinjection of a single worm in this system is reported to be around ~25 s per worm [21]. One of the greatest advantages of this device is that it does not require a high level of expertise with regard to microinjection technique when using this system since the injection microneedle has a restricted (i.e., single) degree of the freedom of movement, making it accessible to beginners.

Automation combined with microfluidic systems

A new microfluidic device system, in combination with an automated computerized algorithm, was developed by Song et al. (2016), [16,22], thus predisposing the microinjection technique from a low throughput to a high throughput technique. The microfluidic device is a two-layer device, where the upper layer (fluid channel layer, blue - see (Figure 5)) is used for loading and mobilizing the worm into immobilization chamber, as well as for microinjection and recovery of the worm, whereas the lower layer (pneumatic valve layer, red - see (Figure 5)) is used to regulate the fluid flow in the upper chamber. The microfluidic device and other auxiliary units required for microinjection were connected to a robotic system in order (i) to regulate the movement and positioning of worms, (ii) to run an imaging algorithm to analyze the worm-loading status and to position the microinjection needle, and (iii) to control the process of injection into the worm. This automated system, combined with a microfluidic chip, attained a rate of ~9.5 s per worm, resulting in a successful high throughput microinjection of C. elegans. Further, analysis of microinjected worms for potential damage, caused by the injection procedure using physiological parameters and survival rate, showed no significant different between the worms subjected to the injection procedure and controls (Figure 5,6).

DISCUSSION AND CONCLUSION

It can be observed that the development of automation and microfluidic chips to ease the complex procedure of the microinjection of the nematode worm C. elegans has only gained momentum in the past five years. Further, it can be noted that the number of microfluidic devices and automations available for various types of worm studies, such as immobilization and microscopy, behavior analyses, metabolomics studies, microsurgery, drug screening and worm sorting [23,24], is greater compared to the available devices for microinjection. Thus, it can be said that updates to the already existing devices and the development of new devices for the purpose of efficient microinjection will be a primary focus among researchers in the upcoming years. Although the above-mentioned devices have increased the efficiency and rate of injection that can be performed, from a few to several hundreds of worms, yet more efficient methods for the development of transgenic lines in worms are anticipated by worm research communities. This can be achieved by designing complex automation methodologies or by developing new strategies, which involve viral-induced infection and the integration of transgenes into a worm’s gonadal oocyte genome, thereby increasing efficiency in the development of transgenic worm lines.

However, it is also disheartening to highlight the fact that the commercial availability of microfluidic devices to enhance worm research is virtually nil [23]. Therefore, an important collaboration between scientists and industry should be encouraged in order to make devices commercially available, which will fulfill the needs of the rapidly growing worm laboratories around the world.

REFERENCES

1. Riddle DL, Blumenthal T, Meyer BJ, Priess JR. (1997) Section I: The biological model. In C. Elegans II (Second Edition). Cold Spring Harbor Laboratory Press: Cold Spring Harbor, NY.

2. Brenner S. The genetics of behaviour. British Medical Bulletin. 1973; 29: 269-271.

3. Gilleland CL, Falls AT, Noraky J, Heiman MG, Yanik, M.F. Computerassisted transgenesis of Caenorhabditis elegans for deep phenotyping. Genetics. 2015; 201: 39-46.

4. Kimble J, J Hodgkin, T Smith, J Smith. Suppression of an amber mutation by microinjection of suppressor tRNA in C. elegans. Nature. 1982; 299: 456-458.

5. Stinchcomb DT, Shaw JE, Carr SH, Hirsh D. Extrachromosomal DNA transformation of Caenorhabditis elegans. Mol Cell Biol. 1985; 5: 3484- 3496.

6. Fire A. Integrative transformation of Caenorhabditis elegans. EMBO J. 1985; 5: 2673-2680.

7. Mello CC, Kramer JM, Stinchcomb D, Ambros V. Efficient gene transfer in C. elegans: extrachromosomal maintenance and integration of transforming sequences. EMBO J. 1991; 10: 3959-3970.

8. Evans TC. Transformation and microinjection. Worm Book. The Online review of C. elegans Biology. 2006.

9. Barber MA. A technic for the inoculation of bacteria and other substances into living cells. J Infect Dis. 1911; 8: 348-360.

10. Feramisco J, Perona R, Lacal JC. Needle microinjection: A brief history. In J Feramisco, R Perona, JC Lacal (eds.) Microinjection. Springer: Basel. 9-15.

11. Shanmugam MM, Santra TS. Microinjection for single-cell analysis. In TS. Santra, FG. Tseng (eds.) Essentials of Single-cell Analysis (First Edition). Springer-Verlag: Berlin Heidelberg. 2016; 85-130.

12. Wilm T, Demel P, Koop HU, Schnabel H, Schnabel R. Ballistic transformation of Caenorhabditis elegans. Gene. 1999; 229: 31-35.

13. Praitis V, Casey E, Collar D, Austin J. Creation of low-copy integrated transgenic lines in Caenorhabditis elegans. Genetics. 2001; 157: 1217- 1226.

14. Berezikov E, Bargmann CI, Plasterk RH. Homologous gene targeting in Caenorhabditis elegans by biolistic transformation. Nucleic Acids Res. 2004; 32: 40.

15. Rieckher M, Kourtis N, Pasparaki A, Tavernarakis N. Transgenesis in Caenorhabditis elegans. Methods Mol Biol. 2009; 561: 21-39.

16. Song P, Dong X, Liu X. A microfluidic device for automated, high-speed microinjection of Caenorhabditis elegans. Biomicrofluidics. 2016; 10: 011912.

17. Zhang M, Wu J, Wang L, Xiao K, Wen W. A simple method for fabricating multi-layer PDMS structures for 3D microfluidic chips. Lab Chip. 2010; 10: 1199-1203.

18. Ren K, Zhou J, Wu H. Materials for microfluidic chip fabrication. Acc Chem Res. 2013; 46: 2396-2406.

19. Fujii T. PDMS-based microfluidic devices for biomedical applications. Microelectronic Engineering. 2002; 61-62: 907-914.

20. Zhao X, Xu F, Tang L, Du W, Feng X, Liu BF. Microfluidic chipbased C. elegans microinjection system for investigating cell-cell communication in vivo. Biosensors and Bioelectronics. 2013; 50: 28- 34.

21. Ghaemi R,Tong J, Ravi Selvaganapathy P, Gupta BP. Microfluidic device for microinjection of Caenorhabditis elegans. In 17th International Conference on Miniaturized Systems for Chemistry and Life Sciences. Freiburg, Germany. 2013.

22. Dong X, Song P, Liu X. An automated robotic system for high-speed microinjection of Caenorhabditis elegans. In IEEE International conference on robotics and automation (ICRA). Seattle, WA, USA. 2015.

23. Muthaiyan Shanmugam M, Subhra Santra T. Microfluidic devices in advanced Caenorhabditis elegans research. Molecules. 2016; 21.

24. Gupta B, Rezai P. Microfluidic approaches for manipulating, imaging, and screening C. elegans. Micromachines. 2016; 7: 123.

Received : 15 Nov 2016
Accepted : 19 Dec 2016
Published : 20 Dec 2016
Journals
Annals of Otolaryngology and Rhinology
ISSN : 2379-948X
Launched : 2014
JSM Schizophrenia
Launched : 2016
Journal of Nausea
Launched : 2020
JSM Internal Medicine
Launched : 2016
JSM Hepatitis
Launched : 2016
JSM Oro Facial Surgeries
ISSN : 2578-3211
Launched : 2016
Journal of Human Nutrition and Food Science
ISSN : 2333-6706
Launched : 2013
JSM Regenerative Medicine and Bioengineering
ISSN : 2379-0490
Launched : 2013
JSM Spine
ISSN : 2578-3181
Launched : 2016
Archives of Palliative Care
ISSN : 2573-1165
Launched : 2016
JSM Nutritional Disorders
ISSN : 2578-3203
Launched : 2017
Annals of Neurodegenerative Disorders
ISSN : 2476-2032
Launched : 2016
Journal of Fever
ISSN : 2641-7782
Launched : 2017
JSM Bone Marrow Research
ISSN : 2578-3351
Launched : 2016
JSM Mathematics and Statistics
ISSN : 2578-3173
Launched : 2014
Journal of Autoimmunity and Research
ISSN : 2573-1173
Launched : 2014
JSM Arthritis
ISSN : 2475-9155
Launched : 2016
JSM Head and Neck Cancer-Cases and Reviews
ISSN : 2573-1610
Launched : 2016
JSM General Surgery Cases and Images
ISSN : 2573-1564
Launched : 2016
JSM Anatomy and Physiology
ISSN : 2573-1262
Launched : 2016
JSM Dental Surgery
ISSN : 2573-1548
Launched : 2016
Annals of Emergency Surgery
ISSN : 2573-1017
Launched : 2016
Annals of Mens Health and Wellness
ISSN : 2641-7707
Launched : 2017
Journal of Preventive Medicine and Health Care
ISSN : 2576-0084
Launched : 2018
Journal of Chronic Diseases and Management
ISSN : 2573-1300
Launched : 2016
Annals of Vaccines and Immunization
ISSN : 2378-9379
Launched : 2014
JSM Heart Surgery Cases and Images
ISSN : 2578-3157
Launched : 2016
Annals of Reproductive Medicine and Treatment
ISSN : 2573-1092
Launched : 2016
JSM Brain Science
ISSN : 2573-1289
Launched : 2016
JSM Biomarkers
ISSN : 2578-3815
Launched : 2014
JSM Biology
ISSN : 2475-9392
Launched : 2016
Archives of Stem Cell and Research
ISSN : 2578-3580
Launched : 2014
Annals of Clinical and Medical Microbiology
ISSN : 2578-3629
Launched : 2014
JSM Pediatric Surgery
ISSN : 2578-3149
Launched : 2017
Journal of Memory Disorder and Rehabilitation
ISSN : 2578-319X
Launched : 2016
JSM Tropical Medicine and Research
ISSN : 2578-3165
Launched : 2016
JSM Head and Face Medicine
ISSN : 2578-3793
Launched : 2016
JSM Cardiothoracic Surgery
ISSN : 2573-1297
Launched : 2016
JSM Bone and Joint Diseases
ISSN : 2578-3351
Launched : 2017
JSM Bioavailability and Bioequivalence
ISSN : 2641-7812
Launched : 2017
JSM Atherosclerosis
ISSN : 2573-1270
Launched : 2016
Journal of Genitourinary Disorders
ISSN : 2641-7790
Launched : 2017
Journal of Fractures and Sprains
ISSN : 2578-3831
Launched : 2016
Journal of Autism and Epilepsy
ISSN : 2641-7774
Launched : 2016
Annals of Marine Biology and Research
ISSN : 2573-105X
Launched : 2014
JSM Health Education & Primary Health Care
ISSN : 2578-3777
Launched : 2016
JSM Communication Disorders
ISSN : 2578-3807
Launched : 2016
Annals of Musculoskeletal Disorders
ISSN : 2578-3599
Launched : 2016
Annals of Virology and Research
ISSN : 2573-1122
Launched : 2014
JSM Renal Medicine
ISSN : 2573-1637
Launched : 2016
Journal of Muscle Health
ISSN : 2578-3823
Launched : 2016
JSM Genetics and Genomics
ISSN : 2334-1823
Launched : 2013
JSM Anxiety and Depression
ISSN : 2475-9139
Launched : 2016
Clinical Journal of Heart Diseases
ISSN : 2641-7766
Launched : 2016
Annals of Medicinal Chemistry and Research
ISSN : 2378-9336
Launched : 2014
JSM Pain and Management
ISSN : 2578-3378
Launched : 2016
JSM Women's Health
ISSN : 2578-3696
Launched : 2016
Clinical Research in HIV or AIDS
ISSN : 2374-0094
Launched : 2013
Journal of Endocrinology, Diabetes and Obesity
ISSN : 2333-6692
Launched : 2013
Journal of Substance Abuse and Alcoholism
ISSN : 2373-9363
Launched : 2013
JSM Neurosurgery and Spine
ISSN : 2373-9479
Launched : 2013
Journal of Liver and Clinical Research
ISSN : 2379-0830
Launched : 2014
Journal of Drug Design and Research
ISSN : 2379-089X
Launched : 2014
JSM Clinical Oncology and Research
ISSN : 2373-938X
Launched : 2013
JSM Bioinformatics, Genomics and Proteomics
ISSN : 2576-1102
Launched : 2014
JSM Chemistry
ISSN : 2334-1831
Launched : 2013
Journal of Trauma and Care
ISSN : 2573-1246
Launched : 2014
JSM Surgical Oncology and Research
ISSN : 2578-3688
Launched : 2016
Annals of Food Processing and Preservation
ISSN : 2573-1033
Launched : 2016
Journal of Radiology and Radiation Therapy
ISSN : 2333-7095
Launched : 2013
JSM Physical Medicine and Rehabilitation
ISSN : 2578-3572
Launched : 2016
Annals of Clinical Pathology
ISSN : 2373-9282
Launched : 2013
Annals of Cardiovascular Diseases
ISSN : 2641-7731
Launched : 2016
Journal of Behavior
ISSN : 2576-0076
Launched : 2016
Annals of Clinical and Experimental Metabolism
ISSN : 2572-2492
Launched : 2016
Clinical Research in Infectious Diseases
ISSN : 2379-0636
Launched : 2013
JSM Microbiology
ISSN : 2333-6455
Launched : 2013
Journal of Urology and Research
ISSN : 2379-951X
Launched : 2014
Journal of Family Medicine and Community Health
ISSN : 2379-0547
Launched : 2013
Annals of Pregnancy and Care
ISSN : 2578-336X
Launched : 2017
JSM Cell and Developmental Biology
ISSN : 2379-061X
Launched : 2013
Annals of Aquaculture and Research
ISSN : 2379-0881
Launched : 2014
Clinical Research in Pulmonology
ISSN : 2333-6625
Launched : 2013
Journal of Immunology and Clinical Research
ISSN : 2333-6714
Launched : 2013
Annals of Forensic Research and Analysis
ISSN : 2378-9476
Launched : 2014
JSM Biochemistry and Molecular Biology
ISSN : 2333-7109
Launched : 2013
Annals of Breast Cancer Research
ISSN : 2641-7685
Launched : 2016
Annals of Gerontology and Geriatric Research
ISSN : 2378-9409
Launched : 2014
Journal of Sleep Medicine and Disorders
ISSN : 2379-0822
Launched : 2014
JSM Burns and Trauma
ISSN : 2475-9406
Launched : 2016
Chemical Engineering and Process Techniques
ISSN : 2333-6633
Launched : 2013
Annals of Clinical Cytology and Pathology
ISSN : 2475-9430
Launched : 2014
JSM Allergy and Asthma
ISSN : 2573-1254
Launched : 2016
Journal of Neurological Disorders and Stroke
ISSN : 2334-2307
Launched : 2013
Annals of Sports Medicine and Research
ISSN : 2379-0571
Launched : 2014
JSM Sexual Medicine
ISSN : 2578-3718
Launched : 2016
Annals of Vascular Medicine and Research
ISSN : 2378-9344
Launched : 2014
Journal of Hematology and Transfusion
ISSN : 2333-6684
Launched : 2013
JSM Environmental Science and Ecology
ISSN : 2333-7141
Launched : 2013
Journal of Cardiology and Clinical Research
ISSN : 2333-6676
Launched : 2013
JSM Nanotechnology and Nanomedicine
ISSN : 2334-1815
Launched : 2013
Journal of Ear, Nose and Throat Disorders
ISSN : 2475-9473
Launched : 2016
JSM Ophthalmology
ISSN : 2333-6447
Launched : 2013
Journal of Pharmacology and Clinical Toxicology
ISSN : 2333-7079
Launched : 2013
Annals of Psychiatry and Mental Health
ISSN : 2374-0124
Launched : 2013
Medical Journal of Obstetrics and Gynecology
ISSN : 2333-6439
Launched : 2013
Annals of Pediatrics and Child Health
ISSN : 2373-9312
Launched : 2013
JSM Clinical Pharmaceutics
ISSN : 2379-9498
Launched : 2014
JSM Foot and Ankle
ISSN : 2475-9112
Launched : 2016
JSM Alzheimer's Disease and Related Dementia
ISSN : 2378-9565
Launched : 2014
Journal of Addiction Medicine and Therapy
ISSN : 2333-665X
Launched : 2013
Journal of Veterinary Medicine and Research
ISSN : 2378-931X
Launched : 2013
Annals of Public Health and Research
ISSN : 2378-9328
Launched : 2014
Annals of Orthopedics and Rheumatology
ISSN : 2373-9290
Launched : 2013
Journal of Clinical Nephrology and Research
ISSN : 2379-0652
Launched : 2014
Annals of Community Medicine and Practice
ISSN : 2475-9465
Launched : 2014
Annals of Biometrics and Biostatistics
ISSN : 2374-0116
Launched : 2013
JSM Clinical Case Reports
ISSN : 2373-9819
Launched : 2013
Journal of Cancer Biology and Research
ISSN : 2373-9436
Launched : 2013
Journal of Surgery and Transplantation Science
ISSN : 2379-0911
Launched : 2013
Journal of Dermatology and Clinical Research
ISSN : 2373-9371
Launched : 2013
JSM Gastroenterology and Hepatology
ISSN : 2373-9487
Launched : 2013
Annals of Nursing and Practice
ISSN : 2379-9501
Launched : 2014
JSM Dentistry
ISSN : 2333-7133
Launched : 2013
Author Information X